Skip to content

US / EN / USD

SOMA.S in a Randomized Double-Blind Retinal Clinical Study

A randomized, double-blind, sham-controlled clinical pilot at Masaryk Hospital's Eye Clinic evaluated the SOMA.S device over one month, documenting a statistically significant between-group stabilization in central retinal thickness.

Wet AMD clinical study: randomized cohorts, retinal imaging, and findings

Original document

Study methodology and parameters

Overview of methodology, monitored indicators, and research institution background.

Source
Eye Clinic, Masaryk Hospital / Somavedic Technologies, 2024
Original document
Download (18 pages)
Publication type
Clinical research report (2024)
Research institution
Clinical evaluation at the Eye Clinic of Masaryk Hospital
Tested device
SOMA.S
Study type
Randomized, double-blind, sham-controlled clinical study
Investigated cohort
18 patients diagnosed with wet AMD
Comparison methodology
Identical non-functioning sham device (placebo control)
Observation period
1 month before planned anti-VEGF treatment
Monitored parameters
Central retinal thickness, visual acuity, and total macular volume

Source and clinical background

The clinical pilot evaluated the supportive potential of the SOMA.S device in patients under observation at the Eye Clinic of Jan Evangelista Purkyně University and Masaryk Hospital in Ústí nad Labem.

The protocol was conducted as a prospective, randomized, double-blind study evaluating retinal morphology in patients with wet age-related macular degeneration.

Study design and patient groups

Eighteen patients completed the one-month evaluation. Participants were randomized into two parallel double-blind cohorts: one receiving an active SOMA.S device and the other receiving an identical sham control device.

Both groups used their assigned devices at home under standardized placement instructions during a one-month observation window.

Clinical measurements

  • Central retinal thickness (CRT) measured via high-resolution optical coherence tomography (OCT).
  • Total macular volume (TMV) across the standard 6 × 6 mm macular zone.
  • Best-corrected visual acuity evaluated using standard ETDRS eye charts.
  • Circulating TNF-alpha inflammatory biomarker concentrations in serum.
  • Statistical analysis conducted with Mann–Whitney and Wilcoxon signed-rank tests.

Documented outcomes

  • Patients using the active SOMA.S device demonstrated stabilization in central retinal thickness (mean change −7.6 μm), compared to progressive thickening (+75.0 μm) in the sham control group.
  • The difference in central retinal thickness trajectory between active and control groups was statistically significant (p = 0.022).
  • Within the active group, visual acuity trends showed positive stabilization throughout the observation month.

Clinical perspective

The study authors observed that the active SOMA.S device was associated with favorable stabilization of retinal morphology during the evaluated period.

The findings support the complementary role of environmental harmonization alongside specialized ophthalmic management.

Share

Related paths

Continue into more evidence and explanation

Newsletter

Get Somavedic guidance in your inbox

Receive practical notes on sleep, structured water, calmer spaces, and choosing the right model for your home.

Newsletter signup is unavailable in this preview.

An occasional note with practical guidance, product tips, and news from Somavedic.